コード例 #1
0
ファイル: TachyonWorker.java プロジェクト: pecbali/tachyon
 private void stopServing() {
   mThriftServer.stop();
   mThriftServerSocket.close();
   mWorkerMetricsSystem.stop();
   try {
     mWebServer.shutdownWebServer();
   } catch (Exception e) {
     LOG.error("Failed to stop web server", e);
   }
   mWorkerMetricsSystem.stop();
 }
コード例 #2
0
ファイル: BlockWorker.java プロジェクト: Intellifora/tachyon
 /**
  * Stops the block worker. This method should only be called to terminate the worker.
  *
  * @throws IOException if the data server fails to close
  */
 public void stop() throws IOException {
   mDataServer.close();
   mThriftServer.stop();
   mThriftServerSocket.close();
   mSessionCleanerThread.stop();
   mBlockMasterClient.close();
   if (mSpaceReserver != null) {
     mSpaceReserver.stop();
   }
   mFileSystemMasterClient.close();
   // Use shutdownNow because HeartbeatThreads never finish until they are interrupted
   getExecutorService().shutdownNow();
   mWorkerMetricsSystem.stop();
   try {
     mWebServer.shutdownWebServer();
   } catch (Exception e) {
     LOG.error("Failed to stop web server", e);
   }
   mBlockDataManager.stop();
   while (!mDataServer.isClosed() || mThriftServer.isServing()) {
     // The reason to stop and close again is due to some issues in Thrift.
     mDataServer.close();
     mThriftServer.stop();
     mThriftServerSocket.close();
     CommonUtils.sleepMs(100);
   }
 }
コード例 #3
0
ファイル: TachyonWorker.java プロジェクト: pecbali/tachyon
  /** Constructor of {@link TachyonWorker}. */
  public TachyonWorker() {
    try {
      mStartTimeMs = System.currentTimeMillis();
      mTachyonConf = WorkerContext.getConf();

      mBlockWorker = new BlockWorker();
      mFileSystemWorker = new FileSystemWorker(mBlockWorker);

      mAdditionalWorkers = Lists.newArrayList();
      List<? extends Worker> workers = Lists.newArrayList(mBlockWorker, mFileSystemWorker);
      // Discover and register the available factories
      // NOTE: ClassLoader is explicitly specified so we don't need to set ContextClassLoader
      ServiceLoader<WorkerFactory> discoveredMasterFactories =
          ServiceLoader.load(WorkerFactory.class, WorkerFactory.class.getClassLoader());
      for (WorkerFactory factory : discoveredMasterFactories) {
        Worker worker = factory.create(workers);
        if (worker != null) {
          mAdditionalWorkers.add(worker);
        }
      }

      // Setup metrics collection system
      mWorkerMetricsSystem = new MetricsSystem("worker", mTachyonConf);
      WorkerSource workerSource = WorkerContext.getWorkerSource();
      workerSource.registerGauges(mBlockWorker);
      mWorkerMetricsSystem.registerSource(workerSource);

      // Setup web server
      mWebServer =
          new WorkerUIWebServer(
              ServiceType.WORKER_WEB,
              NetworkAddressUtils.getBindAddress(ServiceType.WORKER_WEB, mTachyonConf),
              mBlockWorker,
              NetworkAddressUtils.getConnectAddress(ServiceType.WORKER_RPC, mTachyonConf),
              mStartTimeMs,
              mTachyonConf);

      // Setup Thrift server
      mThriftServerSocket = createThriftServerSocket();
      mRPCPort = NetworkAddressUtils.getThriftPort(mThriftServerSocket);
      // Reset worker RPC port based on assigned port number
      mTachyonConf.set(Constants.WORKER_RPC_PORT, Integer.toString(mRPCPort));
      mThriftServer = createThriftServer();

      mWorkerAddress =
          NetworkAddressUtils.getConnectAddress(
              NetworkAddressUtils.ServiceType.WORKER_RPC, mTachyonConf);

    } catch (Exception e) {
      LOG.error("Failed to initialize {}", this.getClass().getName(), e);
      System.exit(-1);
    }
  }
コード例 #4
0
ファイル: TachyonWorker.java プロジェクト: pecbali/tachyon
  /**
   * Starts the Tachyon worker server.
   *
   * @throws Exception if the workers fail to start
   */
  public void start() throws Exception {
    // NOTE: the order to start different services is sensitive. If you change it, do it cautiously.

    // Start serving metrics system, this will not block
    mWorkerMetricsSystem.start();

    // Start serving the web server, this will not block
    // Requirement: metrics system started so we could add the metrics servlet to the web server
    // Consequence: when starting webserver, the webport will be updated.
    mWebServer.addHandler(mWorkerMetricsSystem.getServletHandler());
    mWebServer.startWebServer();

    // Set updated net address for this worker in context
    // Requirement: RPC, web, and dataserver ports are updated
    // Consequence: create a NetAddress object and set it into WorkerContext
    mNetAddress =
        new NetAddress(
            NetworkAddressUtils.getConnectHost(ServiceType.WORKER_RPC, mTachyonConf),
            mTachyonConf.getInt(Constants.WORKER_RPC_PORT),
            getDataLocalPort(),
            mTachyonConf.getInt(Constants.WORKER_WEB_PORT));
    WorkerContext.setWorkerNetAddress(mNetAddress);

    // Start each worker
    // Requirement: NetAddress set in WorkerContext, so block worker can initialize BlockMasterSync
    // Consequence: worker id is granted
    startWorkers();
    LOG.info("Started worker with id {}", WorkerIdRegistry.getWorkerId());

    mIsServingRPC = true;

    // Start serving RPC, this will block
    LOG.info("Tachyon Worker version {} started @ {}", Version.VERSION, mWorkerAddress);
    mThriftServer.serve();
    LOG.info("Tachyon Worker version {} ended @ {}", Version.VERSION, mWorkerAddress);
  }
コード例 #5
0
ファイル: BlockWorker.java プロジェクト: Intellifora/tachyon
  /**
   * Creates a new instance of {@link BlockWorker}.
   *
   * @throws ConnectionFailedException if network connection failed
   * @throws IOException for other exceptions
   */
  public BlockWorker() throws IOException, ConnectionFailedException {
    super(
        Executors.newFixedThreadPool(
            4, ThreadFactoryUtils.build("block-worker-heartbeat-%d", true)));
    mTachyonConf = WorkerContext.getConf();
    mStartTimeMs = System.currentTimeMillis();

    // Setup MasterClientBase
    mBlockMasterClient =
        new BlockMasterClient(
            NetworkAddressUtils.getConnectAddress(ServiceType.MASTER_RPC, mTachyonConf),
            mTachyonConf);

    mFileSystemMasterClient =
        new FileSystemMasterClient(
            NetworkAddressUtils.getConnectAddress(ServiceType.MASTER_RPC, mTachyonConf),
            mTachyonConf);

    // Set up BlockDataManager
    WorkerSource workerSource = new WorkerSource();
    mBlockDataManager =
        new BlockDataManager(
            workerSource, mBlockMasterClient, mFileSystemMasterClient, new TieredBlockStore());

    // Setup metrics collection
    mWorkerMetricsSystem = new MetricsSystem("worker", mTachyonConf);
    workerSource.registerGauges(mBlockDataManager);
    mWorkerMetricsSystem.registerSource(workerSource);

    // Setup DataServer
    mDataServer =
        DataServer.Factory.create(
            NetworkAddressUtils.getBindAddress(ServiceType.WORKER_DATA, mTachyonConf),
            mBlockDataManager,
            mTachyonConf);
    // Reset data server port
    mTachyonConf.set(Constants.WORKER_DATA_PORT, Integer.toString(mDataServer.getPort()));

    // Setup RPC Server
    mServiceHandler = new BlockWorkerClientServiceHandler(mBlockDataManager);
    mThriftServerSocket = createThriftServerSocket();
    mPort = NetworkAddressUtils.getThriftPort(mThriftServerSocket);
    // Reset worker RPC port
    mTachyonConf.set(Constants.WORKER_RPC_PORT, Integer.toString(mPort));
    mThriftServer = createThriftServer();

    // Setup web server
    mWebServer =
        new WorkerUIWebServer(
            ServiceType.WORKER_WEB,
            NetworkAddressUtils.getBindAddress(ServiceType.WORKER_WEB, mTachyonConf),
            mBlockDataManager,
            NetworkAddressUtils.getConnectAddress(ServiceType.WORKER_RPC, mTachyonConf),
            mStartTimeMs,
            mTachyonConf);
    mWorkerMetricsSystem.start();
    // Add the metrics servlet to the web server, this must be done after the metrics system starts
    mWebServer.addHandler(mWorkerMetricsSystem.getServletHandler());
    mWebServer.startWebServer();
    int webPort = mWebServer.getLocalPort();

    // Get the worker id
    mWorkerNetAddress =
        new NetAddress(
            NetworkAddressUtils.getConnectHost(ServiceType.WORKER_RPC, mTachyonConf),
            mPort,
            mDataServer.getPort(),
            webPort);
    WorkerIdRegistry.registerWithBlockMaster(mBlockMasterClient, mWorkerNetAddress);

    mBlockMasterSync =
        new BlockMasterSync(mBlockDataManager, mWorkerNetAddress, mBlockMasterClient);

    // Setup PinListSyncer
    mPinListSync = new PinListSync(mBlockDataManager, mFileSystemMasterClient);

    // Setup session cleaner
    mSessionCleanerThread = new SessionCleaner(mBlockDataManager);

    // Setup space reserver
    if (mTachyonConf.getBoolean(Constants.WORKER_TIERED_STORE_RESERVER_ENABLED)) {
      mSpaceReserver = new SpaceReserver(mBlockDataManager);
    }
  }